THERMORA — PRODUCT SELECTION BRIEF Elastomeric insulation Black elastomeric foam tubes, sheets and formed details for mechanical services. Editorial selection guidance; dimensions in examples are enquiry examples, not confirmed supply specifications. Tested properties require grade-specific company documentation. OVERVIEW Flexible elastomeric insulation is considered for pipework, fittings and equipment in HVAC and mechanical-service projects. The specification starts with pipe outside diameter, service temperature, ambient conditions and the condensation-control objective. Treat joints, supports, valves and protective finishes as part of the insulation package. SELECTION PARAMETERS Product family: Flexible elastomeric foam insulation; tubes and sheet concepts shown Appearance: Black closed-cell foam surface, as illustrated Tube sizing: Match insulation bore to the actual pipe outside diameter in mm Insulation thickness: Determine from thermal duty, ambient conditions and condensation risk Sheet format: State width, length, thickness and whether sheets or rolls are needed Fittings: Include elbows, tees, reducers, valves and support details Joint method: Coordinate compatible adhesive, seams and end joints Facing / protection: Identify any outdoor, UV, mechanical or wash-down exposure Calculation inputs: Service temperature, ambient temperature, relative humidity and duty Quantity basis: Linear metres by pipe size; m² for sheet insulation REFERENCE ENQUIRY — NOT A SUPPLY SPECIFICATION Example enquiry only: 28 mm pipe OD, 19 mm insulation wall, 1,000 linear metres, plus fitting schedule. This is a dimensional example, not a thickness recommendation or confirmed stocked size. GRADE-SPECIFIC EVIDENCE TO REQUEST • Thermal conductivity at declared mean temperatures • Water-vapour resistance and water absorption • Service-temperature limits and fire / smoke classification Measure the pipe, not its trade name List actual outside diameters and required lengths. Keep each pipe size and insulation thickness on a separate line. Design around the service Include operating and ambient conditions so the project team can assess heat flow and condensation. Thickness selection also depends on the exact grade’s properties. Close the system Plan seams, terminations, supports and access around valves. Adhesive compatibility and any exterior protective finish must follow the selected product documentation. FREQUENTLY ASKED QUESTIONS Which thickness should I choose? A suitable thickness depends on the service, temperature, humidity, geometry and the exact insulation grade. Send these inputs for a project-based selection discussion. Are tubes and sheets specified the same way? Tubes require bore, wall thickness and total length. Sheets require thickness, area and dimensions, with a separate allowance for equipment and fittings. Is outdoor protection needed? Identify sunlight, weather and mechanical exposure. Confirm any required facing or protective coating for the selected grade and application. General industry reference: https://www.armacell.com/en-US/mechanical-insulation-for-HVAC-systems Third-party data do not describe THERMORA products.