THERMORA — PRODUCT SELECTION BRIEF Fire-protection boards Mineral board concepts for steel encasement, partitions and service enclosures. Editorial selection guidance; dimensions in examples are enquiry examples, not confirmed supply specifications. Tested properties require grade-specific company documentation. OVERVIEW Board-based protection offers a defined assembly approach for steel encasement, partitions and service enclosures. Performance depends on the whole construction: board type, thickness, number of layers, supports, joints and fixing arrangement. Match the proposed board to the intended system before selecting the cutting list. SELECTION PARAMETERS Product format: Rigid protection board; mineral-board appearance shown Face / edge appearance: Pale-grey matte face with visible mineral-textured cut edge Application scope: Steel encasement, partitions, linings and service enclosures by system Panel dimensions: Provide length × width × thickness in mm Layer build-up: Single or multiple layers only as permitted by the selected design Support construction: Identify steel framing, substrate and support spacing Fixings: Type, spacing and edge distances follow the documented assembly Joints / corners: Coordinate backing, joint treatment and corner reinforcement Cutting schedule: List full sheets, cut pieces, openings and site waste separately Supply unit: Boards or m², separated by thickness and grade REFERENCE ENQUIRY — NOT A SUPPLY SPECIFICATION Example enquiry only: 1,200 × 2,400 mm panels, 1,000 m²; board thickness and layer count to match an approved encasement or partition design. GRADE-SPECIFIC EVIDENCE TO REQUEST • Assembly fire-resistance report and application scope • Density, flexural properties and dimensional tolerances • Moisture behaviour and reaction-to-fire classification Choose the assembly first Identify the protected element and the construction detail. A partition board, a steel encasement board and a duct enclosure may have different requirements. Resolve the perimeter Draw supports, corners, joints and all service openings. Changing the fixings or joint configuration may change the suitability of a tested assembly. Protect the boards in transit Confirm pallet layout, edge protection, dry storage and handling requirements. Provide a thickness-by-thickness cutting schedule to support a clearer material estimate. FREQUENTLY ASKED QUESTIONS Is a board thickness alone enough to establish a rating? No. The rating relates to a complete documented assembly, including board grade, layers, supports, joints and fixings. Can boards be cut for service openings? Provide the opening schedule and service details. Each opening must be addressed within the selected construction and firestop design. What information is needed for a quote? Application, panel sizes, thickness or tested build-up, quantity, cutting needs, destination and required documentation. General industry reference: https://www.promat.com/en/construction/your-project/expert-area/39617/fire-protective-boards/ Third-party data do not describe THERMORA products.